ncConnectTerminals / ncDisconnectTerminals. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。to access the LIN functions of the NI USB-8476 in the following python script: #!/usr/bin/env python from ctypes import * dll = cdll. 3/2. {"delay":300} Sponsored Sponsored Sponsored Sponsored Sponsored. my task is that diagnosing. 1TYPC-001M Amphenol Premium USB 3. OS X v10. NI-488. With high-speed CAN, low-speed/fault-tolerant CAN, andLIN interfaces featuring optional hardware synchronization, you can usetwo or more USB. in the interface, interface modules category. You can press it to stop receiving and displaying frames in the list. I need to send a comand to light up the leds in the slave, but i am not sure how this can be done. Download the. Synchronization via RTSI or any 1/10/20 MHz timebase source. It offers software-selectable, master/slave termination, so you can monitor, log, and test at all points of a LIN network. 2, the helpfile for which I found here. I know plenty of people use LabVIEW purely for data analysis and the like, but there must be a healthy percentage of people doing weird and wonderful things (read: different to your own 9-5 8-5 8-6 wo. For more specialized needs, end of line testing, and embedded systems we have other form factors including C-Series and PXI/PCI. NI 9203 National Instruments NI-9203 cDAQ Analog Current Input Module. Add a comment. Explore a wide range of support content, including examples and troubleshooting. The National Instruments USB-8470 Series 1-Port USB CAN and LIN Interfaces are designed to provide high-speed USB interfaces for. 1 Wi-Fi Direct; 2 Hi-Speed USB 2. . Amphenol Cables on Demand Amphenol CS-USBAM003. 3, 2. Replacing USB-8476 (LIN) with USB-8506 (XNET) 06-23-2017 12:45 PM. I need to send this command to light up. The USB-8473 (Part Number: 779792-01, 194210C-01) is a fast controller area network (CAN) interface for creating applications with the NI-CAN controller. Step 4: Press the other VI's run button. Re: usb8476 Full Diag Frame. 2 drivers, then you can confirm, as I have, that your USB device is supported. 3/2. 0/3. $269. The USB-8476 physical layer requires a DC power supply with an output of 8 to 18 V, as specified in Table 3-10, Bus Power Requirements for USB-8476. NEW SEALED AB 1762-IQ8 /A MicroLogix 24VDC Input Module. USB, PCI. USB-8476 and USB-8476s hardware has a 9-pin male D-Sub (DB9) connector for connection to the LIN bus. 6ft) Datasheet CS-USBAB003. This is a lower cost, mobile solution for communicating to LIN networks. The following figure shows the 9-pin D-Sub connector pinout. The LIN master node requires a 1 KΩ resistor and serial diode between the LIN bus and VBat. Bob Schor. Oct 7, 2012 at 0:21. dll"). Downloads Available: 1. Is it possible to read the serial number of a USB-8476 module in LabVIEW. link But my problem is still not solved. If you have any examp. I am using the USB-8476 to interface the network. The USB-8476 includes NI-CAN driver software, which provides a powerful, frame-based API for rapid application development. Updated Jul 7, 2023 Reported In Hardware USB-8476 USB-8476S Driver NI-CAN Issue Details Wakeup is one task that may be initiated by any node on the bus (a slave as well. I can't get the timing right,. The screenshot illustrates the LIN bus output. Well-Known Member. I am able to send single frame and receive replies. Does someone has an idea of solution? I don't know you but I prefer using the NI-CAN drivers than the NI-xNET one. The USB-8476 LIN interfaces are. 7. 0000 - - Parts : No. Details can be found in the NI 9860 Getting Started Guide. LGA 1700 Intel® 13th/ 12th Gen. NI-CAN has three transmission options: Update Response - this just changes the data in the slave response table. Re: Implement LIN protocol: USB-8476. Options. Any examples ? I really need some help with reading/writing defined data over the USB-8473 module. 11-08-2023 07:25 AM. vi 传输单个帧 。. S. 779793-01 NI USB-8476 1-port. my software consists of labview 8. NI recommends you to Migrate NI-CAN Applications to NI-XNET . Get shipping and tax estimate by adding the item into your shopping cart. Like assign cans been enable using ncSetAttribute function within to. I assigned Port: LIN0 and Baudrate: 19200 (as specified for the product). Approx. Pretty much. Get a quote for a Used USB 8476 Interfaces from Apex Waves, LLC at used-line. Consult NATIONAL INSTRUMENTS's entire NI USB-8476s 1-Port, LIN Interface for USB with Synchronization catalogue on DirectIndustry. Right click on the Sound icon in the Task Tray. The ATA6620 BUY ONLINE a t ni. . 1-Port, USB, LIN Interface Device —The USB-8476 module is a 1-port LIN Interface Device for connecting PCs to LIN networks and devices. set devmgr_show_nonpresent_devices=1. 3/2. dll"). The Gnd pin serves as the reference ground for the isolated signals. Re: Dasylab: Use with LIN Bus Interfaces (USB-8476)? CJ_Butler__DASYLab_Pro. Member 05-13-2008 09:49 AM. • Physical Layer: Low-Speed/Fault-Tolerant CAN. 0. Hooovahh. 5in HDD, SSD [Support UASP] (EC-DFLT) 27,705. Go. NI USB-8476s 1-Port, LIN Interface for USB with Synchronization 1 / 4 Pages Catalog excerpts ni. It offers software-selectable, master/slave termination, so you can monitor, log, and test at all points of a. Solution Unfortunately USB-8476 is not supported by NI-XNET drivers. I am in the process of migrating the VB6 code to VB. EN. 00. Für folgenden Karten müssen Sie daher NI-CAN 2. データ収集アプリケーションにNI USB DAQデバイスを使用しています。このデバイスは、最近までNI Measurement & Automation Explorer(MAX)で正しく認識されていましたが、現在はデバイスの代わりにシリーズ識別子が表示されます。または、MAXで使用しているUSB DAQデバイスが異なるデバイス名で認識され. and the usb-8476 interface which is a master within lin network and a car sunroof controller model which is a slave within lin network form the lin network. Re: USB-8476. On NI USB-LIN products, master termination is software selectable, thus you don't have to connect an external termination resistor to USB-8476S if you enable the Termination attribute . The connector of the product has the following pins: 12 V plus potential. It looks like the new drivers are just not tagged properly on the website. Note: This application is supported on Microsoft Windows 7, Windows 8, Windows 8. From what I can see, they both look like they are running at the same baud rate. 2. Synchronization via RTSI or any 1/10/20 MHz timebase source. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。 Hi, I am a Newbie here. The USB‑8506 excels in applications requiring logging or manipulation of hundreds of LIN frames and. We plan to use the NI USB-8473s as hardware interface an drive from a Python program ? I also suffer with the same issue like described above here . 194210-22L. Our people lookup pulls info from our comprehensive database (containing billions of records), and quickly aggregates them for you. 0 and can driver for ver 2. I have product,this product have LIN functin, I use NI USB-8476 send to this product,then read feedback. NI에 문의하기. NI SpyNI Spy is a utility for monitoring NI-CAN API calls made by applicationswithout recompiling or rebuilding. 00. 2. Examples and documentation of the NI. 07-21-2008 08:58 AM. Solution. On the NI Driver Download page, select your desired Supported OS and Version for the driver. Re: USB-8476 NI-CAN vs USB-8506 NI-CAN interface speed HoussamK. The module is connected (via USB) and recognized by MAX. You can create wrapper code in C# that calls that Dynamic Link Library (dll). Unfortunately USB-8476 is not supported by NI-XNET drivers. item 3 National Instruments NI USB-8476 single port, high-speed CAN 779794-01 National Instruments NI USB-8476 single port, high-speed CAN 779794-01 $156. Welcome to the forums. This unit is sealed in the original manufacturer's box. I don't have any testing of the NI LIN devices with DASYLab 2016 or DASYLab 13. NI-CAN은 다중 CAN (Controller Area Network) 어플리케이션 개발 및 배포를 지원합니다. NI CAN Series 2 products contain several enhancements over Series 1 products, including the Philips SJA1000 CAN controller, improved RTSI synchronization features, updated CAN. Find support information for Intel® HD Graphics 630 including featured content, downloads, specifications, warranty and more. My software consists of labview 8. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. I'm afraid that a 'user' will disconnect and the plug-in a USB module causing. I'm afraid that a 'user' will disconnect and the plug-in a USB module causing. 0 Gbps SuperSpeed] 1m (3. USB-8476 Product Certifications. I do have one of those, which I originally bought for the project, but the customer prefers Vector hardware. NI-CAN은 다중 CAN (Controller Area Network) 어플리케이션 개발 및 배포를 지원합니다. Step 1: Choose the interface. The Lin interfaces can function in master, slave and monitor modes and are fully compatible with 1. PC. . 5. HP 3D DriveGuard (Windows only) The hard drive is mounted directly to the notebook frame, reducing the transmission of shock to the hard drive. Well, I will be appreciated if someone can help me out. 04-24-2013 08:37 AM. 2 for support of the following hardware products (available on ni. The application would require the USB-8476 (Master) to program a Node ID and Zone ID into a slave device that is on the LIN bus. Active Participant. We ship Worldwide. The alternative is using write frame function to wake up the LIN slave device. Minimum system requirements . 6. Potete postarmi qualche esempio? Grazie, Sasa. 0-001: Amphenol Cables on DemandCompliance Electromagnetic Compatibility Information This hardware has been tested and found to comply with the ap plicable regulatory requiremen ts and limits for. 00. This document describes recommendations and considerations for transitioning from the USB-847x CAN/LIN devices to the newer generation of USB-850x NI-XNET CAN/LIN devices. You can also communicate with LIN devices using the a USB LIN Interface Device. Related Links. 2, the helpfile for which I found here. National Instruments : USB-8476 et USB-8476s. A colleague has already successfully used the NI USB-8476 in an application. NI USB-8476 - 1-port USB-to-LIN Interface. For the new tester we are using the XNET USB-8506. A people search at USPhoneBook. 1&Baud rate19200) I referenced the related posts in the forum and used the DirkW upload example (thanks to share). In IsRemote, enter a value of 17 (LIN header frame) or 18 (LIN full frame). 6. NI offers USB-847x CAN and LIN interfaces with an optional hardware synchronization feature, with which the USB interfaces can share timing and triggering signals with other USB-847x interfaces, as well as data acquisition, vision, and motion devices, to achieve true hardware synchronization. 05-14-2012 02:38 PM. e. I was looking for a bit of clarification regarding the capabilities of the USB-8476 LIN module. 6. Page: 1/4National Instruments USB-8473 CAN Interface Device. 12 V ground. 6 | ni. The situation is as follows: I want to use a 8476-module and Labview 2013 to communicate with a product. 本教程将向您展示如何设置ni软件以与labview中的usb仪器通信。 ni-visa驱动程序支持两类usb仪器:usb测试和测量类别(usbtmc)和usb raw仪器。 usbtmc仪器符合usbtmc协议,而usb raw仪器使用其自己的特定通信协议。本教程将介绍两种类型的仪器。 了解有关usb和visa的更多信息 了解有关仪器控制软件堆栈的更多. Just curious to find out what others tend to spend most of their time doing with LV, hardware-wise. It offers software-selectable, master/slave termination, so you can monitor, log, and test at all points of a. Can anyone tell me if it is possible to view the exact start time and end time for a header frame in a lin network using labview. You can use ncWriteNet. National Instruments USB-8472 1-Port USB CAN Interface. SATA 6 Gb/s 256 GB SED Solid State. 2. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。I have a USB-8476 which I am using as a master to communicate with a LIN Slave. Brand. NI-CAN: (Hex 0xBFF621A4) The LIN interface detected that the form of a LIN frame was incorrect. Steps to Implement or Execute Code. High performance USB 2. Find complete product documentation to learn how to get started and use the product. Community. If you run into crashing or redraw issues, try the following solution: Go to Help > System Info and scroll to the Graphics Processor Info section in the System Info dialog box. ncWaitForState. USB-8476 and USB-8476s hardware has a 9-pin male D-Sub (DB9) connector for connection to the LIN bus. The USB-LIN physical layer circuitry interfaces the LIN microcontroller to the physical bus wires. 有关详细信息,请参考 NI 9860入门指南 。. The schedule is responsible for putting the IDs on the bus and the other devices are responsible for putting the data on the bus, after the ID it is responsible is seen. It offers software-selectable, master/slave termination, so you can monitor, log, and test at all points of a LIN network. For all these testers we used the USB-8476. Download new and previously released drivers including support software, bios, utilities, firmware, patches, and tools for Intel® products. Figure 5. Free shipping. With CANalyzer running, I co. Synchronization via RTSI or any 1/10/20 MHz timebase source. Single port, USB, LIN interface device-USB-8476 module is a single port LIN interface device, which is used to connect PC to LIN network and devices. ni-can v2. 0 and J2602 specifications and offer software-selectable master/slave termination. USB-8476 (LIN; 1 port) USB-8476s (LIN; 1 port, with Synchronization) NI-CAN hardware products that pre-date the Series 2 product line are now referred to as Series 1. 相关链接: Products and Services: NI USB-8476 Drivers and Updates: NI-CAN External Site: LIN subbus - News & Events CompactRIO Third Party Module Developers 附件: 报告日期: 05/15/2005 最近更新: 12/25/2009 文档编号: 3LEJ027T. 10-26-2012 05:11 AM - edited 10-26-2012 05:12 AM. National Instruments USB-8476 1-Port USB LIN Interface. The schedule is responsible for putting the IDs on the bus and the other devices are responsible for putting the data on the bus, after the ID it is responsible is seen. Ground looks like pin 3 or 6, VBat on pin 9, and data for LIN on pin 7. Trusted Enthusiast Author 09-30-2015 05:00 AM - edited 09-30-2015 05:06 AM. Trusted Enthusiast 04-30-2008 02:29 AM. 将设备连接至计算机的USB 2. vi to transmit a single frame. NI-CAN은 고속 CAN, 무정지형 CAN 및 LIN 인터페이스와 같은 여러 유형의 CAN 하드웨어 어플리케이션을 위한. 2. Find many great new & used options and get the best deals for National Instruments NI USB-8476 LIN Interface Device 194210E-22L 779794-01 at the best online prices at eBay! Free shipping for many products!Open a service request. Core™ ATX Server Board with 4 x DDR5, 5 x PCIe (1 x Gen 5, 3 x Gen 4, 1x Gen 3), 7 x USB 3. 1-Port, USB, LIN Interface Device—The USB-8476 module is a 1-port LIN Interface Device for connecting PCs to LIN networks and devices. Part Numbers: 779792-01, 194210D-02L. This means that one device on the bus is designated the master, and will pull the data pin high and hold it there. txt 17 KB. Manuals. Mark as New; Bookmark; Subscribe;USB-8476s LINを使用した装置を作成し、客先にて運用していただいています。 USB-8476sはデスクトップPCのUSBポートに直接接続し、デバイスドライバはNI-CAN 2. There are two nodes (master and slave), that communicate properly. 0 and J2602 specifications, and offer software-selectable master/slave termination. Follow the instructions in the installation screen. I am using USB 8476 to communicate to a slave unit in LIN network. Pretty much. This attribute can be enable using ncSetAttribute function within the NI-CAN Frame API. It offers software-selectable, master/slave termination, so you can monitor, log, and test at all points of a LIN network. 0 Gbps SuperSpeed] 1m (3. Options. What you should know is the Frame ID, and then it is able to read the. com) installieren:USB-8476 (LIN) USB-8476s (LIN with synchronization) PCMCIA-CAN, PCMCIA-CAN/2 (Series 1 and 2) Several National Instruments Series 1 CAN hardware products are not supported in this version of NI-CAN. com):Hrachya, I am afraid that this is not solution for my LIN communication problem, because I am using NI USB-8476 adapter. b. 0 connection with data transfer rates up to 480 Mbps. 0-001: Amphenol Cables on DemandDelivery*See Delivery notes. NI 패키지 관리자를 설치한 후 이를 사용해 NI 소프트웨어를 설치, 업그레이드, 관리할 수 있습니다. 이더넷, GPIB, 시리얼, USB 및 다른 종류의 기기에 대한 지원을 제공합니다. This 1-port device is designed to provide connectivity between LIN networks, devices, and PCs. Amphenol CS-USB3. vi. Core™ ATX Server Board with 4 x DDR5, 5 x PCIe (1 x Gen 5, 3 x Gen 4, 1x Gen 3), 7 x USB 3. Download Drivers & Software. First Name Bill Joined Mar 5, 2023 Threads 8 Messages 46 Reaction score 78 Location Halifax, Nova Scotia Vehicle(s) 2023 Bronco Sport Outer Banksこれを動作確認するには、 VISAテストパネル またはLabVIEWアプリケーションを使用して計測器にコマンドを送信し、通信が成功したかどうかを確認します。. com | ni usb-6000 用户指南 组件 原理框图 图3 为ni usb-6000 主要功能的原理框图。 图 3. Created Date: 4/27/2010 11:55:19 AM. 该位置也可以在 <Program Files (x86)>下, 具体取决于您. USB-8472, USB-8472s, USB-8473, USB-8473s, USB-8476, USB-8476s, SJA1000 11bit) 29-bit) J1939 USB-8473 USB-8476 ni 8476 192017-02 ni USB-8476 USB-8473s USB-8476s 847X Digital Visual Interfaces 779792-01: Not Available. Complies with the essential requirements of the following. 1TYPC-000. The differences from what I can see is that: NI: 13-bit time break, ~80us extra space between each byte. 2. 04ffl(Month) Director General of arch AgencyFind many great new & used options and get the best deals for National Instruments NI USB-8476 LIN Interface Device 194210E-22L 779794-01 at the best online prices at eBay! Free shipping for many products!Ho da poco acquistato un'interfaccia USB LIN la "NI USB-8476" che vorrei usare in ambiente LabVIEW 8. 0. US $30. Description. NI provided CAN Frame to Channel Conversion Library in the past but it has been deprecated with the End-Of-Life of NI-CAN hardware and software. Sealed National Instruments NI USB-8476 LIN Interface Device 1-Port 779794-01. 0以降のポートに接続します。 디바이스를 사용자 컴퓨터의 USB 2. com today. Download LDF Starter Kit for LIN 1. All of the documentation states that it is at most LIN 2. cd %SystemRoot% System32. Install NI-CAN version 2. The USB-8476 contains 1 master and 1 slave. Thread starter BillC; Start date Apr 9, 2023; Watchers 1; 1; 2; Next. Software selectable master/slave termination. Proven Zealot. A valid service agreement may be required. USB-8476 (LIN) USB-8476s (LIN with synchronization) PCMCIA-CAN, PCMCIA-CAN/2 (Series 1 and 2) Several National Instruments Series 1 CAN hardware products are not supported in this version of NI-CAN. US $35. 1, extract ZIP file and copy content to: <LabVIEW folder>\user. vi. It specifies that the Windows Vista (32-bit and 64-bit) is the latest release which is officially supported therefore it's behavior on Windows 7. BillC. You can also communicate with LIN devices using the a USB LIN Interface Device. It offers software-selectable, master/slave termination, so you can monitor, log, and test at all points of a. Network, share, and ask questions with other members of the. Next Last. This document describes recommendations and considerations for transitioning from the USB-847x CAN/LIN devices to the newer generation of USB-850x NI-XNET CAN/LIN devices. 0 Kudos Message 1 of 10 (6,038 Views) Reply. OpenGL. If there is still no activity in the volume level indicator. 00. Follow the instructions in Front Panel of " Open_LDF_Database LV2012 NIVerified. LIN: USB-8476, USB-8476s. NI Employee (retired) 07-24-2019 08:31 AM. 5 Inch SATA to USB 3. NI USB-8451 National Instruments Data Acquisition Card DAQ DIO. Re: Implement LIN protocol: USB-8476. Provides support for NI data acquisition and signal conditioning devices. The unit that I have at my desk clearly has an ATA6625C transceiver in it, which is LIN 2. 2, 4 x SATA3, Quad/Dual LANs, and IPMI Visit the European website To get information relevant for your region, we recommend visiting our European website instead. 수리, RMA를 요청하거나, 교정을. • Maximum Transfer Rate: 1,000 kb/s. Solution. 5. When using XNET transceiver cables with an NI 9860 C series module, the NI 9860 itself must also be powered externally (9-30V), in addition to bus power requirements shown in the table. dbc-file. 02-15-2022 07:54 AM - edited 02-15-2022 07:59 AM. When using XNET transceiver cables with an NI 9860 C series module, the NI 9860 itself must also be powered externally (9-30V), in addition to bus power requirements shown in the table. 当您使用数据采集设备测量模拟信号时,模拟信号连接方法会根据接地方法和信号源的类型而有所不同。. Good Morning! We are having a recurring problem on one of our test systems which uses multiple USB-LIN adapters, specifically NI USB-8476 LIN. Software selectable master/slave. 00. Example utilizes the XNET and the CAN API to control a slave on a LIN. Is it possible to read the serial number of a USB-8476 module in LabVIEW. Here is the necessary setup: - first USB-8476 runs LIN Master Send Header Frame Respond and Receive_LV86. Infineon TLE9869QXA20 is a single chip 2-phase motor driver that integrates the industry standard ARM® Cortex® M3 core, enabling the implementation of advanced motor control algorithms such as field oriented control. NI USB LIN. The 8476 is configured in master mode. 00. net examples for the USB-8476? I downloaded the NI-CAN272. Start and Stop Button. 0 connection with data transfer rates up to 480 Mbps. Mark as New;. Header - this causes the master to send a header on the bus. I'm using the USB-8476 on a LIN bus to talk back and forth with my DUT. 14, and a USB-8476 LIN interface) Modified Example "LIN Master Send Full Frame and Receive. 8476. Something went wrong. vi. Hi all, I am working with the USB-8476 and have a question about signal quality. NI-USB-8476LIN device is LIN bus data transceiver which is produced by National Instruments (NI) Co. You should take these. No bus power needed. Welcome to the forums. Install NI-CAN version 2. Solved: いつもお世話になっております。 現在、USB-8476を用いてLIN通信の確認を実施しようとしています。 メインプログラムの環境から、VIの状態では使用することはできないので、C言語での確認になります。 Solution. Step 1 Remote Battery, Charging Port. Luckily I have a known working component from the last tester that I have hooked up to the XNET device. Everything was swell until I started implementing a full frame message, as opposed to a header frames. I am using the NI USB-8476 LIN interface and I need to select the enhanced checksum mode of operation. 0 Gbps SuperSpeed] 1m (3. Allied Telesis AT-MC101XL-20 Fast Ethernet Media Converter. This model uses the Philips SJA1000 CAN controller and the TJA1041 CAN handset that offers useful features, such as listen-just mode, rest. Fully powered by the USB. The Intel® Driver & Support Assistant keeps your system up-to-date by providing tailored support and hassle-free updates for most of your Intel hardware. It offers software-selectable,. The following overview describes the subset of the Frame API features that can be used with USB CAN and USB LIN products. Verify that the GPU is set to OpenGL. 07-21-2008 08:58 AM. LIN interface isolation. The connector of the product has the following pins: 12 V plus potential. Please refer to NI-XNET CAN, LIN, and FlexRay Platform Overview to learn more about NI-XNET. The ATA6620 is fully compatible with the ISO-9141 standard and features baud rates up to 20 kb/s. 2. #1 Best Seller. This document describes recommendations and considerations for transitioning from the USB-847x CAN/LIN devices to the newer generation of USB-850x NI-XNET CAN/LIN devices. . 90. are not included with this equipment unless. led 状态/ 设备状态 led 状态 设备状态 灭 设备未连接或已停止。High performance USB 2. Method 2: Unplug the external Hard Disk Drive. 0 또는 이후 버전의 포트에 연결합니다. When using XNET transceiver cables with a PXIe-8510 or cDAQ-9134/9135 controller ,. The USB‑8506 is a Local Interconnect Network (LIN) interface for developing applications with the NI‑XNET driver. 99. jennygo. These lines can induce currents in or voltages on the NI USB-7846R signal lines if they run in parallel paths at a close distance. Specs: 5V/2. 320/500/750GB 7200 rpm SMART SATA II. Member 11-28-2016 08:30 AM. I am not sure how a master can send this additional 1 byte of data. NI Device Driversをダウンロードして、サポート情報をご確認ください。このダウンロードページを使用して、NI Device Driversにアクセスできます。また、利用可能なすべてのエディションは、このダウンロードページから入手できます。I'm using the USB-8476 on a LIN bus to talk back and forth with my DUT. Stock # 79577-6 . Issue Details I have a USB-8473 High-Speed CAN Interface Device and wish to use it, which driver software do I need to install to be able to program it and see it in NI-MAX? The situation is as follows: I want to use a 8476-module and Labview 2013 to communicate with a product. Where did you find VB. Download and extract the attached file " Open_LDF_Database LV2012 NIVerified ". Description. We ship Worldwide. A little more information from you will help us to help you. USB-8476(NI-CAN)不支持支配或发送LIN唤醒协议功能。. 0 connection with data transfer rates up to 480 Mbps. I see the option to choose classic or enhanced checksum with the NI USB-8476, but is it possible to specify my own checksum? I want to look at a response to a frame sent with an incorrect checksum. Stock # 79577-4 . Explore The LIN Network Physical Layer, Bus Communikation also Protocols.